SlimFlex 5 Controller
The most innovative and flexible water treatment controller available
Introducing flexible programming with ProMinent's SlimFlex 5 Built-in WiFi Hotspot. Enhanced, responsive browser views for smart phones and tablets makes programming fastand easy! Built-in Ethernet and integral data logger creates the total communications packagefor all of your cooling tower and boiler applications.
Request more info
Features
- 5 Flexible control outputs include: ON/OFF setpoint or time based control
- Built In Wireless Access Point and Ethernet
- New Keypad design for easy menu navigation
- Enhanced responsive browser views for Smart Phones and Tablets
- No need to choose - pH and/or ORP along with conductivity all available on the SlimFlex 5 controller
- 6 digital inputs for multiple flow meters or status indicators
- 6 Status LED’s
- 5 Powered relays (2 relays are powered - 3 relays are dry contacts and they can be powered)
- Integral Data Logger
- Conductivity, pH, ORP and Pyxis
- Email out data and alarms
Image Download
Note: Click on image to download
Rating - Detail | Notes | |
---|---|---|
Analog-Digital I/O | ||
Conductivity Serial Sensor | Tower & Integral Flowswitch sensors | Default tower sensor includes 1GPM integral flowswitch & temperature |
Conductivity Sensor | Boiler & Condensate sensors | Standard Sensor |
4-20mA Current | DC isolated, Manual & Auto modes, Interlocking, Alarm | Each optional current output uses a dual sensor card slot |
Manual-Inventory-Inputs | Track drop counts, inventory, tank level, ppm | Alarmed delay prevents premature system ppm alarms |
Communications User Interface | ||
Keypad-LCD | 9 Key tactile feedback, 3 Function keys, 4 line Backlit | |
10/100 Mbps, TCP/IP Ethernet, wifi | HTML micro web server with user definable IP address | Static IP, Browser shows controller in real time |
Controls for ON/OFF & Variable Frequency | ||
Sequential Volume Setpoints | Feed a fixed volume for every make-up controls | Meter only, fault tolerant feed controls |
Blocking | Any of 5 controls may block any other control | Prevents incompatible concurrent controls |
Interlocking | Up to 4 contact sets can be ‘AND’ed or ‘OR’ed | Relays control OFF when contact set opens |
Biocide Event Controls | Each of 5 controls includes 28 timed events | Each control selectable for 1, 7 & 28 days |
System | ||
Electrical | 100-240 VAC, 50/60 Hz, Single Phase | Universal Power Supply |
Fusing for 2 AC powered loads | 6.3 Amps @ 250VAC | Alarm on open AC load fuse |
Surge Suppression | 5 snubbed contacts | RC / Varistor on AC line input |
Enclosure | Non-metallic, IP 65 / NEMA 4X | 13.46” x 8.94” x 3.07” (342 x 227 x 78 mm) (WxHxD) |