Products

gamma/ X Diaphragm Metering Pump


The new gamma/ X is the first metering pump with predictive intelligence. Thanks to its controlled solenoid drive with sensor-free pressure measurement, it detects hydraulic faults even in the case of minimal deviations – immediately and optimally matching its output to the pressure conditions and properties of the medium while protecting the pump and piping systems from overload situations.


Request more info


Features

  • Capacity range from 0.24 GPH to 11.9 GPH, maximum discharge pressure up to 363 psi
  • Simple adjustment of the capacity directly in GPH
  • Configurable discharge stroke, continuous or pulsed dosing
  • Configurable suction stroke duration
  • Stroke rate adjustable from 1 – 12,000 strokes per hour
  • Electronic stroke length adjustment, continuous from 0 - 100% (recommended range 30 - 100%)
  • Suitable for continuous micro-metering from 1 ml/hr thanks to the innovative solenoid control
  • Integrated pressure measurement allows for detection of blocked discharge line, broken discharge
  • lines and air or gas bubbles trapped in the dosing head
  • Acrylic/PVC, PVT (PVDF) and Stainless Steel liquid end material versions
  • Auto degassing liquid ends in Acrylic/ PVC and PVT
  • High viscosity liquid ends (PVT4) for viscosities of up to 3000 cP
  • Large backlit graphic display and status LED’s with 360° visibility
  • External control via voltage-free contacts with pulse multiplier/divider function
  • External control via standard 4-20 mA signal, and scalable adjustment of mA signal to stroke rate
  • Standard internal programmable timer for real-time dependent dosing routines i.e biocides,
  • cooling towers etc.
  • Standard pump capable of accepting 2-stage tank level sensor input, flow monitor input,
  • diaphragm rupture sensor input and control cable input.
  • NSF/ANSI 61 Approved Liquid ends
  • Bluetooth, PROFIBUS°, CANbus interface as an optional feature

Image Download


Note: Click on image to download



Capacity Data

gamma/ X
Pump Version
Capacity at Maximum Backpressure U.S. Max. stroking rate Tubing Connectors O.D. x I. D. Suction Lift SS Liquid end connections FNPT Shipping Weight lbs
psig (bar) GPH* (l/h) ml/stroke Strokes/min in ft (m) in NP/PV SS
gamma/ X with standard liquid ends
1602 232 (16) 0.61 (2.3) 0.19 200 1/4 x 3/16 19.6 (6) 1/4 7.9 9
1604 232 (16) 0.95 (3.6) 0.30 200 1/4 x 3/16 16.4 (5) 1/4 7.9 9
0708 102 (7) 2.0 (7.6) 0.63 200 1/2 x 3/8 13.1 (4) 1/4 8.1 11
0414 58 (4) 3.56 (13.5) 1.13 200 1/2 x 3/8 9.8 (3) 1/4 8.1 11
0220 29 (2) 5.2 (19.7) 1.64 200 1/2 x 3/8 6.5 (2) 3/8 8.1 11
2504 363 (25) 1.0 (3.8) 0.32 200 (8 x 4mm) 13.1 (4) 1/4 10.8 12.1
1009 145 (10) 2.38 (9.0) 0.75 200 1/2 x 3/8 9.8 (3) 1/4 11.2 14.3
0715 102 (7) 3.83 (14.5) 1.21 200 1/2 x 3/8 9.8 (3) 1/4 11.2 14.3
0424 58 (4) 6.34 (24) 2.00 200 1/2 x 3/8 9.8 (3) 3/8 11.2 14.3
0245 29 (2) 11.9 (45) 3.70 200 1/2 x 3/8 6.5 (2) 3/8 11.5 15.4
gamma/ X with auto-degassing liquid ends, 3-port (NPB9/ NPE9)
1602 232 (16) 0.34 (1.30) 0.11 200 1/4 x 3/16 6.9 (2.1) - 7.9 -
1604 232 (16) 0.63 (2.40) 0.21 200 1/2 x 3/8 8.8 (2.7) - 7.9 -
0708 101 (7) 1.8 (6.80) 0.57 200 1/2 x 3/8 6.5 (2) - 8.1 -
0414 58 (4) 3.17 (12) 1.00 200 1/2 x 3/8 6.5 (2) - 8.1 -
0220 29 (2) 4.75 (18) 1.5 200 1/2 x 3/8 6.5 (2) - 8.1 -
1009 145 (10) 2.11 (8) 0.67 200 1/2 x 3/8 9.8 (3) - 11.2 -
0715 101 (7) 3.56 (13.5) 1.00 200 1/2 x 3/8 8.2 (2.5) - 11.2 -
0424 58 (4) 5.28 (20) 1.67 200 1/2 x 3/8 8.2 (2.5) - 11.2 -
gamma/ X with self-bleeding liquid ends, 2-port without bypass PVT7
1604 145 (10) 0.42 (1.60) 0.13 200 1/4 x 3/16 6 (1.8) - 7.9 -
0708 101 (7) 1.50 (5.7) 0.48 200 1/2 x 3/8 6 (1.8) - 8.1 -
0414 58 (4) 3.17 (12) 1.00 200 1/2 x 3/8 6 (1.8) - 8.1 -
0220 29 (2) 4.60 (17.4) 1.45 200 1/2 x 3/8 6 (1.8) - 8.1 -
1009 145 (10) 1.58 (6.0) 0.50 200 1/2 x 3/8 6 (1.8) - 11.2 -
0715 101 (7) 3.40 (12.9) 1.08 200 1/2 x 3/8 6 (1.8) - 11.2 -
0424 58 (4) 5.07 (19.2) 1.60 200 1/2 x 3/8 6 (1.8) - 11.2 -

gamma/X metering pumps with high viscosity liquid ends (PVT 4) have a 10 – 20 % lower capacity rating and are not self priming. Positive suction
is recommended and pumps supplied with ½” MNPT connections.
* The given performance data represents guaranteed minimum values, tested using water as the medium at room temperature.
All data refers to water at 68 °F.

Materials in contact with medium

  Pump head Suction/Discharge Valve Ball seat Seals Balls
NPE Clear Acrylic PVC EPDM EPDM Ceramic
NPB Clear Acrylic PVC FKM FKM Ceramic
PVT PVDF PVDF PVDF PTFE Ceramic
SST Stainless Steel Stainless Steel Ceramic PTFE Ceramic

Auto degassing liquid ends in NP with a valve spring of Hastelloy C and PVDF valve insert. PVT7 versions with PVDF / PTFE wetted parts.
Diaphragm with PTFE face.
Permissible ambient temperature: 14 °f to 113 °F
Average power consumption: 25/30 W
Degree of protection: IP 66/NEMA 4X
FKM = fluorine rubber