Products

**No Longer Available** AEGIS Controller


The Aegis I Controller has been replaced by the New Aegis II Controller!

Please click on this link to find out more info on the Aegis II

 

Process, Waste Water, Boiler and Cooling Tower Applications.

The ProMinent® AEGIS controller is the perfect economical solution for process, cooling, boiler and waste water treatment applications that provides the latest in controller technology.

Benefits

  • Variable Frequency Pump Controls: Accurate and precise chemical feed using pulse outputs. Can also select On/Off control if desired.
  • Data Logging: Data history provides sensor minimum, maximum and average. Also records pump run times, pump feed volume, calculated drum levels, water meter volume, tower run time.
  • Exclusive Thermal Flow Switch: This exclusive design does not require user adjustment or calibration. Operates on 1GPM flow rate with no moving parts.
  • Pump Integration: Select from popular ProMinent® pump models built into the AEGIS programming for accurate ppm feed, tank level and feed volume.
  • Feed Inhibitor using ppm setpoints: Accurate and precise inhibitor feed by simply inputting desired ppm level based on inhibitor chemistry. Use with make-up water meter.
  • Plug and Play Onsite Upgrades: The AEGIS features Plug and Play technology allowing the user to perform simple onsite upgrades and scalability.
  • Program chemical feed based on drop tests: Program chemical feed by entering results of system testing using ppm, ml or drop tests. Enter the new value and desired alarm setpoints for worry-free chemical feed and control.
  • Drum Level Alarms: Provides low level alarms without the use of level sensors. The AEGIS calculates volume fed and subtracts from tank inventory.
  • Communications: Ethernet, cellular, Wireless EVDO.

Features

  • Inhibitor feed using PPM setpoints
  • Volumetric timer controls
  • Relay mirroring
  • Optional ethernet communications
  • MODBUS
  • Industrial and Commerical sales
  • Plug and Play Upgrades
  • ProMinent® thermal flow switch

 

Rating - Detail Notes
Analog-Digital I/O
Conductivity Serial Sensor Tower, Boiler, Condensate & Integral Flowswitch sensors Default tower sensor includes 1GPM integral flowswitch
Fixed Temperature Sensor Input Thermal compensation for both pH and Conductivity Displayed as oF, oC or oK
Fixed 4-20mA Current Loop Input Assignable to control any relay or variable frequency control Single point calibration if 4mA=0
4 max. 4-20mA Current DC isolated, Manual & Auto modes, Interlocking, Alarm Each optional current output uses a dual sensor card slot
7 max. Manual-Inventory-Inputs Track drop counts, inventory, tank level, ppm Alarmed delay prevents premature system ppm Inputs alarms
Communications User Interface
Keypad-LCD 5 Key tactile feedback, 3 Function keys, 4 line Backlit Scan rate 100 mS nominal
10 Base T, TCP/IP Ethernet LAN (optional) HTML micro web server with user definable IP address Static IP, Browser shows controller in real time
Controls for ON/OFF & Variable Frequency
Sequential Volume Setpoints Feed a fixed volume for every make-up controls Meter only, fault tolerant feed controls
Blocking Any of 8 controls may block any other control Prevents incompatible concurrent
Interlocking Up to 4 contact sets can be ‘AND’ed or ‘OR’ed Relays & Frequency controls OFF when contact set opens
9 Biocide Event Controls Each of 9 controls includes 28 timed events Each control selectable for 1, 7 & 28 days
System
Power 120 or 230VAC, 50/60 Hz Line voltage selectable
Fusing for 5 AC powered loads 5 Amps @ 120VAC or 2.5 Amps @ 230VAC Alarm on open AC load fuse
Accessory Power Fused @ 50mA 15-22VDC, Unregulated, Thermally Auto-recovery on fault cleared
Enclosure Non-metallic, NEMA 4X 7.5”W x 11.3”H x 5.5”D (190mm W x 287mm H x 140mm D)
Certifications
CSA: Pending CSA tested to comply with UL (Pending)