multiFLEX M5B/M10B Controller
Boiler Controller
The ProMinent® multiFLEX is a completely customizable microprocessor that provides the highest degree of control and flexibility. Unlock the full potential of your program using Plug and Play Technology and Trackster 3 software.
Request more info
Standard Features
- Control up to 8 boilers
- Web browser accessible
- LAN accessible
- Up to 14 analog inputs or outputs
- Up to 12 digital inputs
- Up to 10 relay outputs
- Compatible with Trackster 3 software
Benefits
- Flexible Control: Multiple processes can be managed using any number of combinations with one controller. Monitor softener regeneration, condensate conductivity and pH. Automate sulfite, amines and inhibitor chemicals. Select from continous or captured sample.
- Data Logging: Detailed data history provides sensor minimum, maximum and average per each log period. Also records pump run times, pump feed volume, calculated drum levels, water meter volume and tower run time.
- Communications: TModem, Ethernet TCP/IP and keypad programmable. Remotely monitor and control your water treatment program on any computer and from anywhere in the world with the use of a standard web browser.
- Plug and Play Onsite Upgrades: The multiFLEX features Plug and Play technology allowing the user to perform simple and economical onsite upgrades.
- multiFLEX Advanced Technology: Maximize your treatment potential with ProMinent’s exclusive features. Rate to Volume, Rate to Stroke, Timed Cycling and Time Modulation provide progressive control, taking your program to whole new level!
- Drum Level Management: Provide digitial low level indication or utilize our analog tank sensor to view level in gallons, inches or liters.
- Trackster Software: Trackster 3 Software completes the package, providing the ultimate in program management. Features such as customized live views, alarm notification, graphing and reporting of all I/O data with exporting capabilities, and email of historical data are all possible with the use of this powerful tool.
- Captured Sample: Flashing does not affect the accuracy of ProMinent’s Sample & Hold Conductivity Control. Repeatable thermal compensation is built into the sampling sequence eliminating the need for frequent calibration.
Rating - Detail | Notes | |||
---|---|---|---|---|
M5B | M10B | M5B | M10B | |
Analog-Digital I/O | ||||
Analog Inputs and Outputs | 1-7 inputs for sensors, 20mA inputs / 4-20mA outputs | 1-14 inputs for sensors, 4-20mA inputs / 4-20mA outputs | Auto configuration on driver installation & removal, DC Isolated, Loop Powered | |
Digital Inputs | 6 Inputs | 12 Inputs | User configurable as water meters or contact sets | |
Relay Outputs | 1SPST, 4 SPDT | 2 SPST, 8 SPDT | Fused in sets of 5 relays | |
Alarm Relay (optional) | Dry Contact set, un-fused | User selected NO or NC | ||
Communications User Interface | ||||
Keypad-LCD | 5 Key tactile feedback, universal characters, 4 line x 20 character, backlit | Scan rate 100 mS nominal, User adjustale contrast | ||
10 Base T, TCP/IP Ethernet LAN | HTML, Telnet Micro Web Server, User Definable IP address & port | Password, User ID protected, Browser shows controller in real time | ||
Modem (optional) | 56K, V.90 Remote Telnet Access | Dial-out on alarms to pager or PC | ||
Data Logging | 600 Entries for each, 26 inputs & 5 relays, Stored in XML format | 600 Entries for each, 26 inputs & 10 relays, Stored in XML format | Adjustable from 5 to 1440 minutes per entry | |
Controls | ||||
Relay ON/OFF | ON/OFF control | Any relay can be configured for any control | ||
Proportional 4-20mA (optional) | User defined control set by sensor or relay control | Software ZERO & SPAN adjustments | ||
Volumetric | User set, measure volume & pump on time then bleeds for user set volume | Sequential control, measures make-up volume | ||
Captured Sample | Sample, Measure, Blowdown, Resample user set timing | Any sensor may be used | ||
Interlocking | 1 to 4 contact set inputs, AND & OR support | Relays OFF when contact set opens | ||
Blocking | 1 to 4 relays may block any other relay | Support for common Oxidant-Inhibitor feed | ||
Alarms - Feed Limit Timers | Minutes per Actuation & Day | User defined on Feed Limit | ||
Feed Verfication (optional) | PPM calculation based on volume feed & cycles of concentration | Fail to Feed is no volume counted after 30 seconds of pump ON time | ||
System | ||||
Electrical | 120/240VAC, 50/60Hz | Switch Selectable | ||
Fusing | 7.3 Amps @ 120VAC, 4.15 Amps @240VAC | Relay Fused 1-5 & 6-10, 6.3A ea. Logic fused @ 1A | ||
Surge Suppression | Relays 2-5 & 7-10 NO Contacts snubbed @ 0.1uF | Controller Isolated from AC line | ||
Accessory Power | 15-22VDC, Unregulated, thermally fused @ 200mA | |||
Enclosure | Non-metallic, NEMA 4X, IP65 | 11.5”W x 13.5”H x 7”D | ||
Certifications | ||||
CSA, CE, UL | CSA tested to comply with UL |